Add to cart
Sale!

Lodar Custom Programming for Shift Receivers

Original price was: £105.00.Current price is: £80.00. Ex VAT

Made in England

In stock

ELP Engineering Ltd large logo
Lodar Custom Programming for Shift Receivers £105.00 Original price was: £105.00.£80.00Current price is: £80.00. Ex VAT

Free UK shipping on all orders over £60

Worldwide shipping from £24.50

  • 30 days easy returns
  • Order yours before 4pm for same day dispatch
Guaranteed Safe Checkout

ELP carries out Lodar Custom Programming which modifies the outputs and operation of  Lodar Shift receivers

Common modifications:
3.5 tonne recovery trucks with electric winch and electric powerpack for the bed

The receiver can be set up to only operate the master output on a certain button press. This is very common on 4 and 6 function recovery trucks with electric winches and an electro-hydraulic clutch or powerpack to operate the hydraulics.

Ifor Williams tipping trailers

A common application is on a 2 function remote control with master output for Ifor Williams tipper trailer bodies which are programmed to only activate the electro-hydraulic powerpack when raising the body. Not active when lowering the body.

Custom Lodar programming:

  • Latching outputs
  • Interlock modification
  • Master output modification to parallel

(See FIRMWARE Software Configuration – All Receivers if you want sequences, buttons turning off others, etc).

Please use the following convention inserted into the Text box to inform us of your requirements:

Note: F1, F2 etc are functions and refer to the button position; see picture.

MOMENTARY OUTPUT – momentary output (standard) – this is standard, so no need to state it.

LATCHING OUTPUT – for a latching output, 1st press turns on, 2nd press turns off, e.g., F3 = LATCH.

INTERLOCKED – state what function doesn’t operate when another button is on, e.g., F1 = INTERLOCKED to F3, F4 (Horizontal interlocks are standard, so nothing stated = horizontal only as standard).

MASTER ON WITH – list all functions you want it to come on with, e.g., MASTER ON WITH F2, F3, this is used a lot on 7.5 tonne vehicles with electrically operated hydraulic pump on the bed and an electric winch.

TIMEOUT – standard is 30 mins on the receiver.

Please list as follows, with examples:

F1 = LATCH

F2 = – (this will give you a momentary output with an interlock with F1)

F3 = –

F4 = –

F5 = INTERLOCKED F1, F2

MASTER = F3, F4

Please feel free to contact us if you need any assistance.

Additional information

Brand

Lodar